Type de paiement: | L/C,T/T |
---|---|
Quantité de commande minimum: | 1 Unit/Units |
Délai de livraison: | 30 jours |
Modèle: HCM110
Generator set |
Genset Model |
HCM110 |
|
Rating Power (KW/KVA) |
80100 |
||
Standby Power(KW/KVA) |
88/110 |
||
Rating Ammeter(A) |
144 |
||
Diesel engine |
General data |
Engine model |
6BT5.9-G2 |
Prime Power(KW/HP) |
92/125 |
||
Standby Power(KW/HP) |
100/136 |
||
number of Cylinder & Configuration |
6 cylinders in line |
||
Bore X Stroke (mm) |
102X120 |
||
Displacement(l) |
5.9 |
||
Compression Ratio |
16.5:1 |
||
Governor type |
Electronic governor |
||
Rated RPM |
1500 |
||
Exhaust system |
Exhaust gas flow(m³/min) |
17 |
|
Max. Exhaust Gas Temperature(°C) |
576 |
||
Max. Exhaust back Pressure(KPA) |
10 |
||
Air intake system |
Aspiration Type |
Turbocharged |
|
Max. intake depression(mbar) |
6 |
||
Combustion air Volume(m³/min) |
5.8 |
||
Fuel system |
Rating Fuel Consumption(l/h) |
23 |
|
75% full Fuel Consumption(l/h) |
23.5 |
||
Lubrication system |
Total oil capacity(l) |
16.4 |
|
Max permissible oil temp(°C) |
121 |
||
Oil pressure at rated rpm(KPA) |
345 |
||
Cooling system |
Total Coolant capacity(l) |
23 |
|
Max. temperature of coolant(°C) |
96 |
||
Fan cooling air flow(m³/min) |
148 |
||
Alternator |
Alternator model |
MGA270-80-4S |
|
Rating Voltage(V) |
400/230 |
||
Rating Capacity(KW/KVA) |
80/100 |
||
Eff.% |
91.6% |
||
Power Factor |
0.8 |
||
Exciting type |
Brushless self-exciter AVR |
||
Voltage regulation |
±1% |
||
No. of Phase |
3 phase 4 wire |
||
Enclosure Class |
IP121 |
||
Class of Insulation |
H |
||
Battery |
Rating Capacity(AH) |
2X120AH 12V |
|
Dimension |
Generator set dimension (LXWXH) |
2280x850x1100 |
|
Weight |
Generator set Net Weight (kg) |
1400 |
Groupes de Produits : Voir plus de produits > Générateur 100kVA